  1. ETN550

    Electrical Outlet Box

    I don't have the latest code so let me ask can I use green colored tape on the wire ends and be okay? I think this was okay in the past, say around 1993. I do have green jacketed THHN I could use. I just used scrap wire laying around as opposed to cutting a fresh length off of the spool. Ground...
  2. ETN550

    MEP recovery, repair, and first start procedure

    I'm new at the MEPs having just acquired two 3kw 016Bs I did the following. Cleaned out the fuel tanks, (Plastic and big opening means wiped out by hand) Cleaned out the fuel water separator and drained. (Lots of water in one of them) Pulled the intake hose and looked in the intake, Pulled...
  3. ETN550

    need help with starter for my 89 3 kw 24v generator

    Post a pic of the generator, not the nameplate. Make sure we can see the engine if it is not an enclosed unit. Many of the 3kw sets were converted from gas to diesel and some were converted from Onan diesel to Yanmar Diesel.
  4. ETN550

    need help with starter for my 89 3 kw 24v generator

    What you say is true for the big vehicle forums where you are pages deep in a day or so. This is a smaller subforum and things move slower. The people here seem pretty knowledgeable and the ones that know your model gen set probably know most of the whole gen set and had a lot of the same type...
  5. ETN550

    need help with starter for my 89 3 kw 24v generator

    These are what I use for the MEP-016b TM 5-6115-615-24P For parts pictures and part numbers TM 5-6115-615-12 Operation and Maintenance TM 5-6115-615-34 Tech Field Manual, similar to the operation manual but a little thinner. Each has some other designations for the other armed services...
  6. ETN550

    Alert: Grounding Lead on MEP-016B and maybe 701A

    The tech manuals state to ground the L2 output for single phase 120 and 240 applications. However, both of my MEP-016B gen sets have the L0 output grounded to the generator frame from the inside of the control box on the L0 inside terminal. Neither the manuals or schematics show this ground...
  7. ETN550

    need help with starter for my 89 3 kw 24v generator

    There is a parts manual for this generator. The top lid outside diameter seal and the water drain seal can be reused many times. The Carquest fuel filters I bought used the cork type doughnut on the top for a tight fit as the lid was tightened down. No issues. If I was starting from...
  8. ETN550

    need help with starter for my 89 3 kw 24v generator

    The spin on oil filter and the drop in fuel filter cross over to auto parts that are available at low cost, under $10.00 each. The air filter was running on e-bay for $35 for three which is pretty good. The air filter system would be easy enough to modify by using radiator hose pieces and...
  9. ETN550

    MEP Frequency Meter is Funny

    Back Up and Running!! I replaced the two capacitors this afternoon and now it works perfect, no drift. I used the household 120vac suicide cord and jumpered to the meter to make the adjustment. Then, running I tweaked it slightly according to the kill a watt. The capacitor that was...
  10. ETN550

    MEP Frequency Meter is Funny

    Derf, n1oty, Thanks for coming through! The gen is the 016B, same as the 701A. The unit I found for $525 is probably made for some sort of large industrial control system hence the price. The container is much bigger so it probably is more complex inside. Do you think the big...
  11. ETN550

    MEP Frequency Meter is Funny

    Maybe "We" can fix it?? Okay, I have been trying to figure out what to do. I pulled the freq transducer out of my other 016B and put it on the bench and hooked up the original meter from the unit that was acting funny. The meter worked fine and exhibited no drift. Conclusion, bad transducer...
  12. ETN550

    MEP Frequency Meter is Funny

    Yeah, I kind of figured you would say it is shot. It was never run open. It is strictly a drift problem. I did see some 55 - 65 1MA transducers but they were too large to fit in the box and very expensive. A resister across the meter is not a problem if I did find a 1 MA provided temperature...
  13. ETN550

    MEP Frequency Meter is Funny

    I'll check Delks. Thanks for the lead.
  14. ETN550

    MEP Frequency Meter is Funny

    The transducer has one cal screw accessable through a plastic screw plug in the housing. It appears to have +/- 5Hz adjustability. In other words when the transducer settles down to 60 Hz and quits creeping I can move the needle full scale. The drift over 20 - 30 min is the problem. It...
  15. ETN550

    MEP -004a. DC circuit breaker issues

    A used board at a reasonable price would be a good thing to have. Those AirPax relays are obsolete but available at $150.00 so to have a board with them intact is worth something. Peter's 12v relay with a socket conversion would be worth it too. Might be possible to cut the case off the...
  16. ETN550

    MEP 002A is ALIVE!

    Not sure how similar the transducers are between your 002 and my 016B but the cal screw in the transducer box will drop the needle from 65 to 60 with about half the range of turn limits of the screw. In other words this might help you match a meter to it a little easier. The system on the 016b...
  17. ETN550

    MEP Frequency Meter is Funny

    I did some testing and now have some info. I bought the Kill a watt and confirmed my house at 59.9Hz and 120VAC. I ran the gen and the meter pegged over 65 when the set was adjusted to 60.0 on the kill a watt. I removed the transducer and disconnected the wires from the meter. I...
  18. ETN550

    aux fuel pump question

    What ever the situation the pump should probably not run dry for any length of time, especially if there is loud hammering noise. The clicking noise when running with fuel is the check valves working. The fuel adds resistance and provides lubrication and cooling. I only run the pump in aux...
  19. ETN550

    aux fuel pump question

    I have 016Bs but visually the pumps look the same. The 016B does cycle the pump to fill the tank. However, the pump test is to deadhead the pump and measure the pump output pressure. When this is done the pump stops cycling when pressure, about 7 psi, is made. I would conclude that your pump...
  20. ETN550

    MEP Frequency Meter is Funny

    Okay, then I have my assignment! 1. Buy a Kill a Watt. 2. conduct calibration with 120VAC household. I did just read the big "Frequency Meter and Transducer" thread and gained valuable info. while you were preparing your reply! Thanks for that info too. Thanks to everyone. I'm going to...