Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!
Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.
As far as I can tell that 7 pin CAN connector is not present on the standard AAMPS sets. The "Remote" connector on the DCS is a 14 pin connector and uses RS-485 for communication.
I poked around and from what I could gather only 1060's and 1070's that were specially modified for use in a...
I see the output voltage on the meter jittering and all over the place at times when the voltage and frequency goes whacky.
There may be a AC Voltage Regulator issue.
WOT = Wide Open Throttle
Inverter removal isn't too bad.
6 exterior bolts
2 left side bracket bolts
Disconnect all wires and plugs
Unbolt the two cable clamps from the inverter
Remove "L" bracket under inverter
Unbolt contactor and move to bottom
Wriggle the inverter out
Yes
I make WiFi Remote Start Parameter monitoring systems for..
831A
802A
803A
804A/B
805A
806
1030
1040
They are listed the the Classifieds in Parts for Sale
Set is running Wide Open Throttle. It shouldn't be. The SLC100 Governor Controller (GC) is shot. One of the classic symptoms of a factory GC failure. Also not lifting off the magnet is a sign too.
No LED ON in K15 indicates the inverter isn't making power. May be due to running WOT at...
The fuse is on the input of the sets battery charger. If that popped the battery charger is probably toast. The set can run OK without it on the batteries until they wear down.
Is the LED inside of K15 ON when running? If on it indicates the inverter is making power, at least L1 is, it powers...
It could be that resistor R13 is bad or the contacts 13 14 in S8 aren't making good contact. The purpose is to put R13 in parallel with R12. This cuts the burden resistance from 7.5 ohms to 3.75 ohms.
The CT's generate a current proportional to the load on the respective winding set. The CT's...