Search results

  1. R

    Help, My FDECU-5 is bi-polar

    After reading other threads about problems with generators, I bought a can of DeOxit and douched the daylights out of S6 and then cycled it about 100 times on both my 804a and 804b generators. It seemed to show improvement on both. Before, the short light would come on 90% of the time the...
  2. R

    Where oh where might the TM be? (Applied Companies GETT Generator and ECU)

    If you need R22, I believe either it became illegal at the start of this year or will at the end of the year. Robert
  3. R

    Who is handling the general surplus now that GL is out?

    I had been with Govliquidation since 2002 and DRMO (the good old days) before that. This new animal, Go-Dove, is not making much sense to me at this point. I guess it’s good that I have almost everything thing I need/want and nowhere to put it since it looks like my buying days have come to an...
  4. R

    MEP 003 Starting and low rpm problems

    My 003 is very cold natured also. I just went out and cranked it up with only 10” of preheat and it started right up ( only 74 degrees right now). This particular set also requires one to hold the switch in start for approximately 15” after the oil pressure is up or it will quit as soon as you...
  5. R

    Parts for aux fuel system for MEP-016D?

    Careful use of a torch and sometimes weed eater line can fill a crack or hole in plastic. I assume this was a diesel tank but blowing out the fumes after sitting in the sun all day helps to reduce the chance of a loud surprise. Robert
  6. R

    60 kw generator injector pump issue

    I have found a service manual online for this series 1100 engine. This is a 1104 with a Delphi DP210 series IP which is self bleeding. I will be on trips the next two days with lots of waiting so I will have time to gather information. I have learned that the top solenoid is indeed the stop...
  7. R

    60 kw generator injector pump issue

    Best I can tell, this is a RG 1104 engine. The tag (which is very hard to get to and read) says this is a RG51236. It also has 2442/1800 but unable to find what that correlates to. Still trying to find detailed information. The IP has Delphi cast on the side. The tag on IP says Perkins type...
  8. R

    60 kw generator injector pump issue

    Not sure what they are for. There are a couple more places for connections around the engine also. I am getting on the trail for a detailed shop manual. I would love for it not to be a drive issue for the IP. The IP only has the two solenoids going to it and I believe I have accounted for...
  9. R

    60 kw generator injector pump issue

    Thanks for the suggestions. Probably the most likely is that whatever turns the IP has sheared off. It looks like I will need to remove the radiator and that plate in the first picture to get to the mounting bolts for the IP. If it has, getting it timed correctly may be a challenge. I did...
  10. R

    60 kw generator injector pump issue

    It cranks fine, more than two minutes, 10 seconds at a time. Robert
  11. R

    60 kw generator injector pump issue

    Through Ft Bragg GL, I bought this fuel pumping unit. It has a 60 kw civilian generator powered by a 4 cyl turbo diesel Perkins engine, 20 hp motor driving a fuel pump and associated electrical switches and panel. The control panel is a Deep Sea Electronics and it says the engine only has 112...
  12. R

    MEP 002a running but getting no power

    You should set the throttle and never touch it. You will damage these type of generators by running them at low or idle rpm. Then there is wet stacking. That may happen by running it without a load for a long time. It is good to run generators at high load periodically and get it good and...
  13. R

    MEP-802 / MEP-803 startup routine

    On a 804a in prime and run, you will hear silence since it has a mechanical pump. To prime, you must unscrew the cap and pump it up until you feel resistance, then tighten the cap. You will hear the pump run in auxiliary fuel. The 804b has an electric main fuel pump. Robert
  14. R

    MEP-803A Starting kVa capacity

    It has been my experience that my 804a will usually not start my FEDCU-5s without tripping the short circuit light or tripping the main breaker, once in a blue moon, it will actually get the compressor running. My 804b will start them (actually get the compressor going) about 25% of the time...
  15. R

    MEP-804A cranks but no start, suspect solenoid on side of injection pump

    Thanks for your help Guyfang. I will probably try to raise the voltage some if it needs alot of starter in the future . I believe the original crank was the first in at least six months and there was probably air in the lines from the IP to the injectors since it cranked right up after that...
  16. R

    MEP-804A cranks but no start, suspect solenoid on side of injection pump

    It's alive!! Just like 155mm and Guyfang said, the magnetic pickup (MPU) was the problem. Why didn't I ask 5 months ago? I did try to use the troubleshooting guide but it does not seem to address the MPU, it goes into playing with the injector pump (IP) which I really did not want to do...
  17. R

    MEP-804A cranks but no start, suspect solenoid on side of injection pump

    Got the tire fixed and have it on my land now with a lock on the hitch so it doesn't decide to walk off. I didn't steal this at $3600 all in. I believe three other folks were bidding on it. I called Stateline about 1630 but the lady said everyone had already booked, will try tomorrow. I...
  18. R

    MEP-804A cranks but no start, suspect solenoid on side of injection pump

    Thank you 155mm and Guyfang, I will check things out and report. I have spent all morning retrieving my latest treasure from Ft Bragg. It is some kind of aviation fuel distribution apparatus with a 60 kw generator and a 20 hp electric motor on a trailer. The plan is to use this to power my...
  19. R

    MEP-804A cranks but no start, suspect solenoid on side of injection pump

    MEP-804A cranks but no start, turned out to be mag pickup I bought this 804A with about 46 hours and it now has ~120. I am sure it is the correct hours since it was so clean when purchased. It has been reliable with the only exception being the fuel system. Two or three times, it has lost...
  20. R

    Any 30/60kw genset gurus?

    I would suspect it denotes different engines. My MEP 804A has an Isuzu engine while my 804B has a Yanmar. I remember looking at some 805 (I think) generators that had John Deere engines. I believe I remember browsing some older GL ads and those had White engines. Robert