Thats exactly what they did. The A0 specced 4 different type relays, 12-24, 4 or 5 pin. Using the resistors on the 24v control circuits they can spec one type relay 12v 5 pin…
Almost looks like the bend angle is the worst/aligned with the fore axis when the cab is raised. what does the angle look like when the cab is lowered. there is a good view with the grill removed when lowered.
yea the long slot is to allow cab suspension travel, but the control should be in...
The vent they are probably referring to is over on the second fuel filter boss, large hex plug up on top. on a non return system like on my tractor you would need a vent to purge air. On our looped/return system, they are designed to self purge, so it is just as easy to simply pump any air...
Because of the crane arch folding back over itself to cradle the tire, it kind of limits the size of the actuator, unless you really lengthen the structure to move the base attach point. This would have the advantage of an actuator with a longer stroke with the attach point farther up/out on...
Yep, would be very interesting, but considering the 5 solid = fatal fault coming from the manufacturer does not indicate this is possible… but they are in the business of selling modules:)
What General said, they should have used the word drain. You open the drain and use the pump to pump out the water/fuel sample from the bottom of the filter bowl. That is actually one way to confirm if your bypass flapper is sealing. If you open the bottom drain, nothing should happen except...
Yea this is not an RV slide-out that only needs a few hundred pounds of force to operate. Tons of electric actuators 100-1000# capacity. Pickins get pretty thin above 1K# of op force…
And that has been a fairly frequent question over the past few years, both here and in other groups since I joined this club. “My CTIS has 5 solid lights”, mine included… That failure alone in what is a relatively small community puts CTIS into the high failure category IMO, not to mention...
yea a >5000# electric linear will be expensive. It may also not be very fast... There is a reason we do so many things with hydraulics:)
Sounds Interesting, Good luck!
Well K26 is driven directly by the transmission. Do you have both transmission inputs, Battery and IGN? Allison controls some outputs by providing a ground, and others by providing a voltage. The voltage it uses for output is the battery input. Thats why the Vehicle interface Module on the...
Check my YT channel username Rronmar. Did a vid on the typical primer issue and resolution. Not sure which port you pulled on the primer assembly, but that may keep it from working... 16-18 pumps to lift fuel from tank to primer with an empty line, ~20 more)with full filters) to feel...
well if brakes work while hazards do not, relay K-10 switches between the two, and since it energizes when brakes are applied, if it is a 5 pin relay(has de-energized contacts), that would point me toward the flasher assembly.
You can simulate flasher input by disconnecting its connector and...