  1. K

    MEP-804A Quad fuse problem

    Gentlemen. After downloading the TM Voltage Regulator Test procedure this is what I found. When the meter should have read between 4 and 12 VDC I got 0 VDC On AC Volts what should have read 210-280 VAC I got 20 VAC The ohms test was also a failure and the pot was far from smooth in fact so...
  2. K

    MEP-804A Quad fuse problem

    I will download the TM and work on doing that in the next couple days as time permits. Thanks for your help to this point and I will be back with updates ASAP.
  3. K

    MEP-804A Quad fuse problem

    I at this time not done any trouble shooting on the A1. I am definitely learning as I go on this piece of equipment. The first time I started it up everything seemed fine for the first couple minutes. Then Phase and voltage both dropped off. And before you ask no I did not throw any switches...
  4. K

    MEP-804A Quad fuse problem

    114v so NO
  5. K

    MEP-804A Quad fuse problem

    KTK 3 less than 600v
  6. K

    MEP-804A Quad fuse problem

    I just purchased this gen set and everything seems fine on start up. Untill I release the start switch at which time the quad fuse blows. I see no glaring problems and need some help.