• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. M

    MEP-806A Transformer Replacement Part

    Perfect, thank you!
  2. M

    MEP-806A Transformer Replacement Part

    Thanks, I'll have to look into getting a Kill-a-watt meter, but I do have a multimeter. And yes, I do have it set to 60 But I should be able to get an accurate reading from the back of the gauge itself and the 110 outlet, correct? Sorry for the confusion/questions, just want to make sure I'm...
  3. M

    MEP-806A Transformer Replacement Part

    So I received your Voltage regulator upgrade and installed without issues. It seems to have fixed the problem we were having, but now it is showing a low frequency on the gauge, at ~48 Hz. The unit fires up just fine, the generator comes online, and all warning lights are clear, but the gauge is...
  4. M

    MEP-806A Transformer Replacement Part

    Awesome! I will send you and email here shortly. Thanks!
  5. M

    MEP-806A Transformer Replacement Part

    Hey thanks for the help! So I found your post for the updated voltage regulator and just have a couple questions before I pull the trigger on it. This does bypass the transformer I am currently attempting to repair/replace, correct? And if so, and if I'm understanding everything correctly...
  6. M

    MEP-806A Transformer Replacement Part

    Hey thanks for the quick response! I will have to look into getting that fuse mod installed. And I did not, test for that as of yet. Do you happen to know what pins are 11 & 12 on the transformer? I have not been able to find an accurate pinout spec for it. I do believe the Volt Regulator is...
  7. M

    MEP-806A Transformer Replacement Part

    Hello, I have a MEP-806A Generator that will start and run, but not produce any voltage when holding switch to start or releasing. I have a contactor trip under voltage light illuminated. I did the 4.1 voltage regulator test, from the TM, and determined that the transformer may be the issue, as...