Just a little exaggeration. I like to verify wiring from point A to point B. Never know if someone was in their landing wires to the wrong terminals. I would however start with the P&ID and meter.
So just to update, I changed the S5 interrupter switch and now I have voltage at the output terminals. Green light on. thank god, didn't really want to start cutting zip-ties to trace wires in that wire forest lol. The last question I have is how long do you typically have to hold the start...
Not yet...When I got it the genset it didn't run. After cleaning the tank, a couple of new hoses, and installing a new pump with an injector block cleaning it runs great now. I then proceeded with testing the generator. It runs with no faults and has 120/208 readings on gauges and one side of...
Thanks, I found them. All are in the same direction grey side to the left. Ill have to look closer in the morning when light. Thanks a bunch for the support!
Yes sir. I have tested S5 and it seems to be bad per the TM results. K1 contacts are not pulling in and the interrupter light works when I push it in. I pulled and tested K1 via 24vdc and it checks out. I then proceeded with the switch and got bad readings when I followed the manual. Ordered a...
Good day. I have a bad S5 INTERRUPTER switch. I can't find a replacement anywhere. Will part number 8906K4519 for the 803 work? TM for the 804 has part number 88-21076. Is there a good site to acquire parts? thanks