  1. R

    803a dies above 75%

    So I've only had it a couple months and THOUGHT they were changed out The first picture is the fuel filter, plenty of water and not much liquid came out. It ran better as I posted. Then the water seperator came in today and I swapped it. Notice light watery fluid as well. The right can...
  2. R

    MEP-803a load testing

    Hilarious... I can't stop laughing
  3. R

    803a dies above 75%

    Update: replaced fuel filter and it's better. Handles load changes better. ONLY stalls when going from 11,500 to 12,500w. Much better than before. I also found fuel bowl missing spring. So in the hunt for that. Then change the fuel seperator. Then I'll go from there. Lastly I'm going to...
  4. R

    803a dies above 75%

    Thank you. Question do you know what amperage you were pulling per leg?
  5. R

    803a dies above 75%

    Thank you. Will you elaborate on what you used (setup) to equal such a load?
  6. R

    803a dies above 75%

    Perfect. That is where they all are positioned. Thanks
  7. R

    803a dies above 75%

    Amp draw pics. I think it's overloaded and that's the issue. Should have stuck with 3 smaller heaters. Each leg 11.5/ 28.4= 39.9 per
  8. R

    803a dies above 75%

    Left to right temp readings
  9. R

    803a dies above 75%

    Hello everyone, I've followed lots of information found here and online. My 803 has 2 new IPs and two older ones. I took the advice and utilized heaters to provide a load. Initially 2 heaters would only give 10k watts max which the genset had no issues. I recently found a 7500 (6250 on...
  10. R

    Currently Running a MEP-803a During Beryl Hurricane - Question

    Awesome.. just load tested mine last week in preparation.
  11. R

    Currently Running a MEP-803a During Beryl Hurricane - Question

    How far south are you? I'm in Pearland. Be good to know another owner near by, just in case.