I just pulled a Rectifier out of the generator and could read 1N120 and could not read the last digit. So I ordered 3 1N1206A and 3 1N1206RA diodes.
Thanks for the help guys Really appreciate it
Rog
I just pulled a Rectifier out of the generator and could read 1N120 and could not read the last digit. So I ordered 3 1N1206A and 3 1N1206RA diodes.
Thanks for the help guys Really appreciate it
Rog
Looking for part numbers
Looked at TM-5-6115-585-12
Looked at TM-5-6115-585-24P
Looked at TM-5-6115-585-34
None of the above gave me the part numbers. Anyone know where else to look.
I am wrong about that, we never tried removing the 12 volts and reconnecting the other leads while running. Didn't want to make the situation worse than it already was.
I had been using the generator to power a Lincoln Cracker Box welder and had done about 3 hr of welding with it, when one time...
My MEP003A will work when I flash the field with -12VDC on TB3-5 and +12VDC pm TB3-6. I have two extra regulator boards and have tried both of them with no success.
When I measure the voltage on the reg board terminal 12 and 18 during starting, both show +24 volts. It drops to 0 when I release...