• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. R

    MEP-002A power problem

    I think I found it. I measured the output leads with my meter with the main breaker closed and got one that measured as open. I removed the main breaker and have one set of contacts that is not closing. It probably does close a bit with vibration, which is why I was able to measure any...
  2. R

    MEP-002A power problem

    More information: I tightened up the loose connections in the connection box and reassembled it to the generator. I started it up and mesured with my meter 120 VAC from both hots to neutral, and 240 vac between the hots. So I powered it down and hooked it to a portable power panel. when...
  3. R

    MEP-002A power problem

    Thanks for the information. I opened up the connection box and found a couple of loose connections. Hopefully when I get it put back together it works.
  4. R

    MEP-002A power problem

    I have an MEP-002a that has a power issue. I've been testing it periodically and putting a 1kw heater on the convenience outlet to load it. Yesterday I decided to hook it up to the house using my transfer switch and a cable, which has worked fine in the past. The switch on the generator is set...