They don't read shorted and I tested in circuit with a 9 vdc batt and the MOSFET's fire as seem as should. I am at a loss. I am showing 60 HZ on freq meter and I perform the test in the MEP-803a manual and get all readings but on 7 & 8 I read nothing while holding start and after changing...
what if I am getting 120 vac from convenience outlet until start is released and vac then drops to 22 vac? What do I check then. The Voltage Reg had 2 Burned/Bad diodes and I replaced. B4 that, I was getting 0 vac. Thank you for your help.
Are the cvt1's in a mep-002a different from a cvt1 in a 5kw 400 cps? Google, 400 cps distribution box and click image. Scroll down to pics and read will not work in mep-002a but most parts will work. I just bought that box and installed the cvt1 in my mep-002a and just fried it after 10...