Start the unit
Have the AUX selected
siphon fuel out of the day tank
Watch inside the tank, and fuel level
Listen to when the AUX kicks on
Stop the siphon
Watch the day tank fill
Watch your fuel level move up
Listen to when the AUX pump turns off
On all machines it will be a...
@Papi Chulo
Start in this thread.
MEP-802A MEP-803A Filters and Parts | SteelSoldiers
2nd post has quick links to important stuff.
3rd post has links to all the TM's you need.
Welcome.
In a more layman's terms.
It is meant for keeping 100% uptime of power.
#1 generator is running, and it needs to be serviced. #2 generator is fired up, use the box to sync, transfer, shut down #1 generator and service.
@ribs1
Before you end up with 50 gallons of diesel on the floor......
Set scene
In the front of the unit, right next to the fuel fill, behind the panel is where the AUX fuel pump sits. OK, good, you now know where it is.
Inside the fuel tank, you have another metering float system. (The main...
Start in this thread.
MEP-802A MEP-803A Filters and Parts | SteelSoldiers
2nd post has quick links to important stuff.
3rd post has links to all the TM's you need.
Welcome.
OK, We have a new Winner in California.
2016 Cummins Power Generation MEP-1041 10kW Generator Set
MEP-1041 10KW 400Mhz Generator on Trailer. Sold 1/18/2023
Selling for $7,600 before Fees, Taxes, and shipping to California.
Not all bulkhead fittings are the same.
A proper A3816 nitrile well-nut works fine. Don't over tighten and split it.
The correct 1/4" Brass Bulkhead Fitting (Includes Viton O-Ring) works fine.
There are many options out there. The 2 items work. If you use something else, and have problems. That...
Power the generator up.
You are running it to low a RPM
You want the 120/240 running at 60Hz >speed it up<
Yes, the 2 cylinder will be even worse at a slower idle.
Note: Don't do any fancy youtube processing. Just straight upload. Don't shoot video in portrait mode.
Here is one of my MEP-802A...
Remove it, and set it on the ground.
I had a MEP-802A sitting on a pallet in the back of a truck after coming home with it. It bounced and rattled the lifting eyes. Sounded like someone ringing bells.
Set it on the ground, problem solved.
I have almost the same here.
Generator connection choices | SteelSoldiers
A behind the collar unit, a Interlock in your panel
If you have a "Main Brand Panel" you should find a listed interlock kit. Then supply what size breakers you want, wire size accordingly, and input receiver. Wires...
The NOCO G7200 has the capability to charge a dead battery. You simply hold the mode button, and then select the "Supply"
After a while, switch the mode back to 12v AGM charge, and let it do its thing.
Safety first. "Ground the generator"
Coolant all full?
NOTE: Spin-on fuel filter is sometimes a bear to get off. It actually does come off. The cup canister fuel filter has a little tiny rubber gasket around the top of the cup. You can use a dab of grease to hold it inplace, and make sure it...
Start in this thread.
MEP-802A MEP-803A Filters and Parts | SteelSoldiers
2nd post has quick links to important stuff.
3rd post has links to all the TM's you need.
Welcome.