    Wet Weather Issue With MEP 831A

    Thanks for your help sir output contact test is a go. The K15 was the culprit I found a working 3k and swap out the relay to test and the contacts close a provides 120 VAC at the lugs . I found another nsn for the k15 it is 01-509-9898 I fed log the one you provided and they both came up as...
  2. D

    Wet Weather Issue With MEP 831A

    I have follow troubleshootings steps for circuit interrupter won't close and tested k1,k13 the switch itself. The circuit interrupter dummy light light up when I press it but contacts won't close. I have 120 vac coming from the top of the inverter box .the end of my testing procedures says...
  3. D

    Wet Weather Issue With MEP 831A

    Do anyone by chance have the nin for the AC relay the TM 9-6115-639-13&p only list the DC relays. I may have a DC relay in the k15 area led lights up green I notice on a working gensets k15 is red led. I have 3 mep 831 with the problem contact switch won't close no voltages out the lugs but get...