• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Dumb newbie with questions....

Chuck76

Member
90
1
8
Location
Salisbury. NC
just bought a 1980? M35a2 that has been bobbed. With anything, it has a few bugs that need to be worked out. At the moment, tring to figure out the headlight wiring. I have looked through the TM's, and didnt find any wiring diagrams. I'm sure they're in there, I just missed them. Can anyone point me in the right direction?

Brakes are an issue also. Turning 53" tires, shes not gonna stop on a dime, but sometimes I wonder when she's gonna stop... really hate to run over someone. I found some of the brake stuff in a TM, so I'll get after them shortly. I would like to know how or what I'm gonna need (exactly) to build my own pressure bleeder.

Clutch is gonna be swapped out in a week or so also... great advice already found on it.

If I can figure out how to post pics, I will.
 

hndrsonj

Senior Chief/Moderator
Super Moderator
Steel Soldiers Supporter
7,584
363
83
Location
Cheyenne, WY
Click on "Forum" at the top of the main page, go to the deuce section. Almost everything you asked is in a sticky.:beer:
 

Speddmon

Blind squirrel rehabiltator
Super Moderator
Steel Soldiers Supporter
4,640
28
38
Location
Cambridge, Ohio
I would like to know how or what I'm gonna need (exactly) to build my own pressure bleeder.
You'll need a cheap 1 gallon garden sprayer from your local hardware store. I used about 3 feet of 1/4" nylon hose rather than the hose that came with the sprayer.

Some small spring clamps for the hose.

1/4" barb to 1/4" NPT fitting

Fittings to go from 1/8" NPT to 1/4" NPT

An air line coupler set (male and female) like used on 99% of the air compressors sold today (Usually 1/4" NPT)

Spare master cylinder cap from a junked duece somewhere (not necessary, but handy to have because it saves you from having to remove the vent from your cap all the time to hook up the bleeder you can just replace the cap to bleed)

Attach hose to sprayer, put fitting in hose and attach female air line coupler. Put male coupler half in spare master cylinder cap with 1/8" to 1/4" NPT adapter. That's about it. Put fluid in the sprayer, put cap on master cylinder and pump until you have a few PSI of pressure. While bleeding, DO NOT allow pressure to run out and DO NOT run out of fluid in the sprayer...easy
 

Recovry4x4

LLM/Member 785
Super Moderator
Steel Soldiers Supporter
34,012
1,808
113
Location
GA Mountains
Download manual TM 9-2320-361-20. You will find the wiring schematics in the appendix. All else are in the stickies including the power bleeder thread.
 

Chuck76

Member
90
1
8
Location
Salisbury. NC
thanks gents, New problem came up. I went to get fuel, shut her off, filled her up, started her, idled around the building, and she died. the engine spins over, but no fire. tried ether just to see if she would start, nothing. Now th eclutch is shot, and she has to be moved b4 the store closes, or it gets towed.
 

lawdog1623

New member
274
1
0
Location
Texas
You gotta love this forum.theres a ton of experience here and i learn every day. Again, watch those stickies...they have helped me so much.
 
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks