I believe that cpf240 is correct.
I recently installed new glow plugs and changed plugs from 24 to 12 volt feed.
Experienced the same no start issue with a longer than normal WAIT light symptom.
Measured the voltage on the top of the GP relay -- 12.8 volts during the wait cycle.
Measured the voltage on the bottom of the relay --.238 volts during the wait cycle.
I am assuming that the glow plug relay was marginal and failed with the increased current draw.
Replaced relay and it starts fine now.
Karl