• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

MEP005A 5volts only

peapvp

Well-known member
Steel Soldiers Supporter
1,118
1,243
113
Location
Basehor, KS
Desoldere Q1. I got 167 across both legs. This diode has two legs unlike the others. If I did this right., then it's not blocking properly.
That’s an scr with one leg being the gate and the other two anode and cathode -
 

pf.hal1984

Member
48
25
18
Location
Killeen Tx
That’s an scr with one leg being the gate and the other two anode and cathode -
So I take the the threaded portion would be anode or cathode? Either way i get nothing across except by testing both legs. I take it this one is shorted out?
 

peapvp

Well-known member
Steel Soldiers Supporter
1,118
1,243
113
Location
Basehor, KS
So I take the the threaded portion would be anode or cathode? Either way i get nothing across except by testing both legs. I take it this one is shorted out?
Procedure to Test the SCR with the help of Multimeter:
  • To test the SCR, keep the Multimeter into Ohmmeter mode.
  • Connect the positive output lead of the multimeter to the anode and the negative lead to the cathode.
  • The multimeter should indicate no continuity.
  • Touch the gate of the SCR to the anode.
  • The multimeter should indicate continuity through the SCR.
  • When the gate lead is removed from the anode, conduction may stop or continue depending on whether the multimeter is supplying enough current to keep the device above its holding current level.
  • If the multimeter indicates continuity through the SCR before the gate is touched to the anode, it indicates that the SCR is shorted.
  • If the multimeter will not indicate continuity through the SCR after the gate has been touched to the anode, it indicates that the SCR is open.
 

pf.hal1984

Member
48
25
18
Location
Killeen Tx
Procedure to Test the SCR with the help of Multimeter:
  • To test the SCR, keep the Multimeter into Ohmmeter mode.
  • Connect the positive output lead of the multimeter to the anode and the negative lead to the cathode.
  • The multimeter should indicate no continuity.
  • Touch the gate of the SCR to the anode.
  • The multimeter should indicate continuity through the SCR.
  • When the gate lead is removed from the anode, conduction may stop or continue depending on whether the multimeter is supplying enough current to keep the device above its holding current level.
  • If the multimeter indicates continuity through the SCR before the gate is touched to the anode, it indicates that the SCR is shorted.
  • If the multimeter will not indicate continuity through the SCR after the gate has been touched to the anode, it indicates that the SCR is open.
JAN2N689 NSN 5961-00-226-8697
 

peapvp

Well-known member
Steel Soldiers Supporter
1,118
1,243
113
Location
Basehor, KS
Btw. did you adjust your Rheostat to 12VAC with T3 connected or did you do that before connecting to T3 - just double checking
 

peapvp

Well-known member
Steel Soldiers Supporter
1,118
1,243
113
Location