loosegravel
Just a retired mechanic who's having fun!
- 504
- 892
- 93
- Location
- Enumclaw, Washington
I posted a message a few weeks ago about this MEP-804A unit. When I picked it up from the GP auction site in Chehalis Washington it had an A/C volt meter in place of the M9 percent power gauge. I’ve sourced the correct gauge (used on eBay) and installed it today. From the wiring schematic I know that wire #120A is positive and 124A is negative. One thing that isn’t in the schematic is the shunt/spring that was on the back of the A/C volt meter that I removed. Does it belong on the percent power gauge? This shunt/spring is located on the back of the M2 hertz gauge. That gauge is not working at the moment. It stays right where it is in the picture when I run this machine regardless of the frequency adjustment (which works fine) I’ve also shut down the machine and switched to 50 hertz. Still no action. The machine is producing power. Long post, I know. Thanks as always for the help!