Mep-003 won't continue to produce power

Angelo190471

New member
20
8
3
Location
BRADENTON FL
I purchased a 003 couple days ago. He had it rigged up to some commercial heaters and acs to load test it, and it seemed to be making power fine. I go to try it here and it would produce power for 10 seconds then the volt and hertz gauge will drop down just about all the way. Every time I try and restart it, it will do the same thing. The generator part just won't stay running.
He bought and maintained this with no intention of selling, but unexpected move forced him to sell. He did a handful of upgrades, like the spin on filters and I believe it was the voltage regulator.
What should I check?
Screenshot_20220517-074051.pngScreenshot_20220517-074032.png
 

Scoobyshep

Well-known member
1,144
1,528
113
Location
Florida
yea this looks modified. if I had to guess either the regulator is damaged or insufficiently sized and is not able to maintain the field.
 

Angelo190471

New member
20
8
3
Location
BRADENTON FL
it will make 260 volts on its gauge, aslong as i hold the start switch. pretty much as soon as i release it, it drops down almost to nothing. wouldnt that be more so a problem with flashing the generator then it would be with the vr?
 

Scoobyshep

Well-known member
1,144
1,528
113
Location
Florida
it will make 260 volts on its gauge, aslong as i hold the start switch. pretty much as soon as i release it, it drops down almost to nothing. wouldnt that be more so a problem with flashing the generator then it would be with the vr?

No when its in start the regulator is being bypassed for the flash. The avr takes over when not in start
 

Chainbreaker

Well-known member
1,797
1,995
113
Location
Oregon
I have one Triple Jim's Lakeland AVR boards installed in one of my gensets. It is excellent and an "upgrade" (better components, heatsinking, etc.) over the OEM board. You should PM Triple Jim member here and ask him to respond to this thread as how to test his board to verify functionality.
 