• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

MEP007B Low voltage

mrichard76

New member
20
3
3
Location
Louisiana
I recently purchased a MEP007B that was load tested, producing correct voltage etc. Only issue then was the hertz meter was not functioning. Got it back home and now voltage meter also quit working and was only getting 120 volts across legs when measured at the lugs. Tried adjusting throttle to get 60 hertz (measured on multi meter) and was reading 137 volts across lugs, neutral to lugs or ground to lugs 8 volts. No electricity at 120v convenience outlets. Power coming into voltage meter at connections is 137v. Any ideas what's going on here?
 

Guyfang

Moderator
Staff member
Moderator
16,768
24,086
113
Location
Burgkunstadt, Germany
When you hold up the S2, (Start Switch) and let the engine go through its starting phase, do the volts and hertz meters move at all? Do them come up, until you let the S2 go? Or make any movement at all? What voltage do you get at the 120 volt outlets? Do you get any idiot lights, after letting the S2 go, other then LOW VOLTAGE?
 

mrichard76

New member
20
3
3
Location