Hello,
Once again I ask the collective for guidance on a question I came up with regarding upgrading a 60 AMP to 200 AMP gen.
Please reference this YouTube:
at the 16:30 mark. The creator references that there is a second cable supplied in the conversion kit that goes to the first battery 12V terminal supplied in his upgrade kit. I was only supplied a single new 24V battery cable that goes to the 24V terminal, and not a second cable for this 12V connection. I am not sure why there seems to be a difference. The instructions I have do not reference this 12V second cable. The Kit I received is HMMWV M998 M1026, 200 AMP GENERATOR ALTERNATOR Upgrade KIT PN 57K3520.
My first question is, do I need to run my own supplied 12V cable from the regulator to the 12 battery connections? Or is this second cable not necessary? Or should I run one?
Second question. The author also states at 17:15 mark, that his instructions state to run a supplied jumper from the 14V regulator terminal to ground on the 4 speed transmission (which I have). But he states that is not necessary based on a thread here? My instructions state to run this jumper also, but does not mention the transmission type.
Any help would be most welcome, as I do not wish to experiment and perhaps burn out a brand new regulator!
Thanks in advance!
Once again I ask the collective for guidance on a question I came up with regarding upgrading a 60 AMP to 200 AMP gen.
Please reference this YouTube:
at the 16:30 mark. The creator references that there is a second cable supplied in the conversion kit that goes to the first battery 12V terminal supplied in his upgrade kit. I was only supplied a single new 24V battery cable that goes to the 24V terminal, and not a second cable for this 12V connection. I am not sure why there seems to be a difference. The instructions I have do not reference this 12V second cable. The Kit I received is HMMWV M998 M1026, 200 AMP GENERATOR ALTERNATOR Upgrade KIT PN 57K3520.
My first question is, do I need to run my own supplied 12V cable from the regulator to the 12 battery connections? Or is this second cable not necessary? Or should I run one?
Second question. The author also states at 17:15 mark, that his instructions state to run a supplied jumper from the 14V regulator terminal to ground on the 4 speed transmission (which I have). But he states that is not necessary based on a thread here? My instructions state to run this jumper also, but does not mention the transmission type.
Any help would be most welcome, as I do not wish to experiment and perhaps burn out a brand new regulator!
Thanks in advance!