Leece-Neville 100 Amp Generator rebuild

WWIILBird

Member
Steel Soldiers Supporter
87
14
18
Location
Northern NJ
My gauge in my 1980 M35a2C kept going from center of the green when idling down to yellow as soon as I started driving and continued toward boarder line yellow/Red. When I shut down the engine and restart it after a while I'm back in the green until I start driving again. It was suggested that I have it bench tested so I dropped it off. Fellow wants $400 to rebuild it telling me something in the back of the generator is shot from spinning and rubbing or something like that and he has to machine new parts so the cost is mostly labor. This generator has a fat cable that screws on. Every TM document I've read and internet searches I've done (including SS) seem to talk more about 60 amp and 25 amps or conversion kits for 25 amp to 60 amp conversions. Nothing I've seen addresses this 100 amp generator. So I have a couple of questons, does anyone know the history of why they went with this model as I can't find much info on it, is it an anomoly and can you swap it for a different model that will fit the bracket with screw on? and is $400 too much to pay for a rebuild? I really haven't seen any rebuilts for sale and checked Kublos he doesn't have any . Thanks Nick
 

gimpyrobb

dumpsterlandingfromorbit!
27,786
755
113
Location
Cincy Ohio
If you want to stay stock, you might have to bite the bullet. I got a single wire 100amp alt for about $225 new for my 725 a couple years ago.
 

Stalwart

Well-known member
1,739
33
48
Location
Redmond, WA
Usually the problem you describe is from having belts that are too loose. As the belt speed increases the belt climbs higher on the pulley due to the increased acceleration required to curve around the pulley. I have seen alternators act normally at idle and actually STOP spinning entirely when the engine speed increases.
 

WWIILBird

Member
Steel Soldiers Supporter
87
14
18
Location
Northern NJ
I had a fellow who works on trucks check my belts and he said they had the right tension. I put new belts on in the spring when I pulled my radiator. Interestingly, I slaved a generator last week and each time I hit the starter switch on the MEP16A a high pitched squeel came out of the engine compartment. I had the truck idling at about 1000 RPM.
 

emmado22

Moderator
Super Moderator
Steel Soldiers Supporter
7,058
148
63
Location
Mid Hudson Valley NY
ASSUMING the genny bracket is stock to the truck when it rolled off the assembly line, the 60 amp genny will bolt right to it. I have never seen a decue with anything but a 25 or 60 amp genny, but in the military things happen to get trucks fixed. The 100 ampers will fit where the 60's are and vice versa. 100 amp genny in a deuce is very unusual, the 60 is fine. I have seen 60 and 100 amp gennys sell at shows for $100-200. $400 is nuts, you can find them cheaper than that..
 

Stalwart

Well-known member
1,739
33
48
Location
Redmond, WA
Interestingly, I slaved a generator last week and each time I hit the starter switch on the MEP16A a high pitched squeel came out of the engine compartment. I had the truck idling at about 1000 RPM.
If that happens your belts ARE NOT at the correct tension OR your pulleys are glazed smooth and don't provide enough traction for the belt. You should use a belt tensioner or re-calibrate your friend, it should not be squeaking the belt with a heavy load, especially as low as 1000 rpm.
 

good

New member
3
0
1
Location
Huntington Beach
Problem with my m998 Humvee charging starts in the green with the dash after a few mi

Have you figured out my charging quite yet talked to a couple guys they said that the brushes inside are going bad that's why I beginning it starts to charge when it heats up they get loose and goes down to about 23 Waltz it first starts up I'm at about 27.9. Belts that feel real tight but they do slap quite a bit any suggestions
 
Top