• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. S

    ⁸What causes under voltage error in MEP-805B? Sometimes it runs fine, but ultimately will show this errer and stop generating. Seems to heal itsel

    Three phase load. A is 208, B is 105, C is 105. It varies. Sometimes B and C are 195ish. And sometimes when I start it, they are all 208. It's random.
  2. S

    Who can refurb a MEP-805B?

    I'm near Clayton in SE Oklahoma. I have three MEP 805B generators. One has a voltage issue. One the aux fuel pump is not working. The third one has a bad voltage regulator as well as other issues. We've had two outfits, Bison and Clifford try to fix them. Cost me a lot of money to figure...
  3. S

    Who can refurb a MEP-805B?

    Done
  4. S

    ⁸What causes under voltage error in MEP-805B? Sometimes it runs fine, but ultimately will show this errer and stop generating. Seems to heal itsel

    Load on each phase varies. This morning phase 1 was 216, 2 = 110, 3 = 108. Typically, phase 1 is 216, 2&3 are 195. I get a low voltage error and it runs but produces no electricity. It's 4pm now. I fired it up and all three phases are 208.
  5. S

    ⁸What causes under voltage error in MEP-805B? Sometimes it runs fine, but ultimately will show this errer and stop generating. Seems to heal itsel

    On a whim, I fired it up. Now it healed itself. It must be a short in something. Suns out and warmed it up. Any ideas?
  6. S

    ⁸What causes under voltage error in MEP-805B? Sometimes it runs fine, but ultimately will show this errer and stop generating. Seems to heal itsel

    B & C are both well below A. We need all three phases operational if that's what you are asking. It shuts itself down if phases B&C are too low, like below 200.
  7. S

    ⁸What causes under voltage error in MEP-805B? Sometimes it runs fine, but ultimately will show this errer and stop generating. Seems to heal itsel

    Started using exact procedure on display cover. Held to start for 5 seconds. All legs registered, but two legs were at 200 and the one was 215. Held down start and reset switches, but no changed. Closed the circuit in parallel with another working generator. It shared the load, but didn't...
  8. S

    Who can refurb a MEP-805B?

    besides Green Mountain. I have three generators. All need to be refurbished. They run, but not 100% One is on a trailer. The other two will need to be trailered. I'm in Oklahoma and prefer not to drive to NH, but will if that's the best place to get the work done. The two generator...
  9. S

    MEP-805B Aux fuel pump

    The auxiliary fuel pump quit working on our MEP-805B. Fuel line is not obstructed. Pump seems to get power. We swapped the fuel pump with a known good one. Ideas?