  1. T

    Mep 803a voltage regulator

    Would be nice to have a spare or two.
  2. T

    MEP-803A smoking under load.

    Turns out my load bank has too set of references for the Kw switches....one for single phase and another for 3 phase. When I thought I was running 15kw I was actually runing 12
  3. T

    MEP-803 install with automatic transfer & remote monitoring

    I added a Kohler ATS to my house....works great.
  4. T

    Water Separator Filter Removal

    Anyone have any tips or idea how to remove the filter from an MEP803a. It really is stuck on there.
  5. T

    MEP-804B wont start without Starting spray

    Turns out it was/is the shut off solenoid sticking
  6. T

    MEP803A Over Voltage

    Update. I changed the VR and added the quad wind fuse. It is working as good as new. Thanks everyone
  7. T

    MEP-803A smoking under load.

    Ran it under load...bluish white smoke burned off. But noticed injector 1 might be sticking. Going to run some cleaner with the fuel next time
  8. T

    MEP-803A smoking under load.

    Thanks Ray We just. I’ll run her tomorrow and post some pictures. I also have blow by coming out of the oil filler 😢
  9. T

    MEP-803A smoking under load.

    Wouldn’t the overload trip and shut down the generator? Putting 10kw on it takes the percent meter south of 80% on every 803 I have.
  10. T

    MEP-803A smoking under load.

    222hrs. I don't think it wetstacking.....because i don't see the usual black specs flying out. But I was going to top off the coolant and do just that....to see if by chance its burning coolant. to get it to 75% I'll have to run over 10kw load...probably close to 15kw
  11. T

    MEP-804B wont start without Starting spray

    This machine started giving me issues a few weeks ago when it would only start with Ether...then it would run fine. But now it wont. I'm guessing its a fuel issue....was going to start at the filters and then pump. Any suggestions?
  12. T

    MEP-803A smoking under load.

    I have an 803A that I bought several month back and it ran fine. I can't remember if I load tested it or not. It starts right up and sounds great. But when I put a load on it...it started to smoke a lot more than usual. Steady smoke....bluish white. take the load off....smoke goes away...
  13. T

    MEP803A Over Voltage

    Update. So I took the top cover off. The S8 switch looked perfect and clean. But I still sprayed it down and manipulated it back and forth. Over voltage would go away on a couple starts, then it would come back. Sprayed it down some more and it seemed to be working properly without the...
  14. T

    MEP803A Over Voltage

    I’m think I’m going to tow it back to my house to give me something to do during lockdown.
  15. T

    MEP-805A Control head on MEP-805B Genset

    The Box that bolts onto the genset with all the gages, regulators etc. 6110-01-397-2112 CAGE 60177 PN 88-21577 Control Box Assembly , 30kw
  16. T

    MEP803A Over Voltage

    So today I drove out to where I have it stored. Started up...and again, shut down due to over voltage. I had my meter with me this time. I started it up and flipped the battle short for it to stay on. I checked voltage at the convenience Outlet and lugs....both less than a volt. Even...
  17. T

    MEP803A Over Voltage

    I believe it is.....because I starated it when I received it. I added fluids....started right up, rand for a while and I shut it down. Yesterday I went to start it to put a load bank on it, and it would start and shut itself down. Nothing has been manipulated since I received it. I'm...
  18. T

    MEP803A Over Voltage

    I haven't looked at the TM yet. I was just on here making a different post and figured I'd ask away. I have an 803A that I purchased over a month ago. It started and ran great. Yesterday I was going though my generators, started and ran this one....but it started and turned off and...
  19. T

    MEP-805A Control head on MEP-805B Genset