Anyone have a defective MEP-831A battery charger available?
I need one I can partly disassemble to do some reverse engineering.
I'd pay for shipping.
If it's fixable I'll repair it and return it to you.
(Posting here instead of classifieds since no one would likely look in the parts wanted...
Looking for suggestions for a oil pressure sender (not a switch) for a MEP-831A.
1/8 NPT, reasonably priced, with either a nut/bolt terminal or spade connection.
Resistance of sender not critical.
Since my venture into developing the replacement MEP831A Governor Controllers was a success I thought I'd revisit MEP remote start/stop with parameter monitoring.
About 2 years ago I developed a similar capability. However the control components were a closed design, didn't use WIFI and was not...
MEP-831A SLC100 Governor Controller
Having purchased a couple of MEP-831A's I found that the SLC100 Governor Controllers are problem prone. The two Tier 2 Reset units I purchased with just 2 hrs on the clock both randomly exhibited surging issues as well as random WOT issues. Adjustment of...
Got a MEP-831A that I suspect has a bum governor controller.
Was reading the TM -13&P and I suspect there is a typo regarding voltages that should be seen on the controllers D & E LOAD input terminals.
TM 9-6115-639-13&P dated 30 APRIL 2010 page 19-1 paragraph 3. PDF page 160.
It reads...
3...
When the inverter voltage output switch is set to 120V what is the allowable current loading on L1 & L2 terminals?
I understand the max current at 120 volts is spec'd at 31 amps.
Can 31 amps be drawn from say L1-L0?
Or can L1-L0 only provide 15.5 amps max and L2-L0 only provide 15.5 amps max?
I...
A GLA auction closed yesterday at 4:00 PM. Won a couple of gen sets. :-D
Credit card already on GLA system for payment.
When does the Invoice usually become available on-line for downloading after a auction closes?
Another thread here inspired me to design and build a remote start and generator parameter reporting system for my 802 to use in conjunction with my PV battery bank solar charging system and thought this may be of interest to other Mep owners.
I've designed, built and coded the 802 Autostart...
Got my 802A running today :-)
I plugged in a 1,000 watt heater into the outlet and within a couple of seconds the heater stopped.
No power at the outlet.
According to the schematic CB3 controls the power to the out. I looked all around the control box and no CB3 to be found.
What I did find...
Bought my first MEP-802A and picked it up at Ft Meade on 3/24/14.
I dealt with both Dan and John there with arranging a pickup date/time and the actual pick up of the genset.
Both guys were very pleasant and helpful. :-D
Upon arrival I checked in with John, he had the paperwork all ready and...
Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!