So I installed an ADVR-054 , I excited it with a little tickle is working perfect. Was an extremely simple install 5 wires. I do appreciate all the help getting it dialed in.
Have you ever switched out the excitation assembly for a aftermarket piece? Its cheaper, but stated that sometimes you have to give it a little excitation
ok, I have -34 tm open. I think I found what I am looking for on page 270 excitation system assembly figure 8-15. The testing procedure I am having trouble understanding. Probably my lack of knowledge.
Think I found the nsn# for replacement I found the regulator nsn 6110-00-030-7815 for...
Started the set There is nothing on the AC meter, Do not have 120 at the 120 convenience receptacle.
When I Close the circuit breaker (push the S3 up, the DS-6 (circuit breaker light) does not come on.
So It is the second fuel pump. the one that is closest to the tanks on the side of the machine. I unplugged both of them and It didn't pop so I plugged them in individually and it started smoking... I figured that is a good indication.
NSN 2910-00-930-9367 ,MS 5132-2
Facet Part # 480517
Onan...
Nope I am not sure if its 10 seconds. I will check the fuel pump and then disconnect the alternator. Do a once over on the wiring harness, I hear that the wiring on the oil pressure switch can be tight and can pull. appreciate the direction to start.
took a couple of years of German in high school... a long time ago... Looks like a good beer..:)
I received the new CB and installed it.
Started the unit and it now runs for a second and the circuit breaker pops. I turned the battle short on and flipped the switch to run. I can hear the fuel...
yeah but its pretty amazing what can be delivered locally. I have read through a lot of peoples posts about problems they are having and you are a Huge resource. should be celebrated.
no not really stressing over this. I just want it to work correctly and I can wire in a 7.5 panel mount breaker.
you say cheap american beer...I have no idea whats cheap or not i am allergic to hops so never got into it.
that is a comprehensive list! will see what i can find! definitely owe you a beer.
can I use a surface mount 75 amp breaker to replace the push pull that feeds the panel?
I ordered the one off ebay. will be here in a week.
SO ALL interchangable?
The listing from ebay. price is 100.00
Prestolite JCG6001A Contactor 3PST-DB 350A 120/208V NSN 5945-01-010-5911
This is a used Prestolite JCG6001A Contactor 3PST-DB 350A 120/208V NSN 5945-01-010-5911- Came to us from the DoD with a condition code “A”
The inside is corroded I ended up snapping off several bolts taking it apart, and there was definitely arcing going on inside.
So the numbers on the side of the CB2 are
JCG-6001A
current amp- 350/POLE
FREQ Hz - 50/60/400
CONTACTS - 3PST NO
OPERATING VOLTS - 28 VDC
MAIN CONTACTS...
So I pulled it and opened it up, one of the two microswitches is stuck down, and there is definitely some corrosion. the three contact points on the top are not all capable of contacting at the same time, look like they have arced a bit. Can I find a new one somewhere? I can clean it up but...