• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. P

    MEP-802A 5K Gens

    Gens were taken to auction facility on 3/2/17 so good luck all
  2. P

    MEP-802A 5K Gens

    1. S/N fz06334 hrs 420 service date 9-13-16 2. rzb01772 hrs 188 9-19-16 3. fz01996 hrs 390 11-10-16 4. fz03985 hrs 552 10-26-16 5. fzb03258 hrs 311 9-20-16 6...
  3. P

    MEP-802A 5K Gens

    I am not linking to auctions, I am not linking to anything that I would consider that is breaking the rules, in my opinion. I could be wrong. Just putting information out regarding 10 gens,that is all. If it is a violation,mods I am sure will kill this thread. Wasn't trying to do harm.
  4. P

    MEP-802A 5K Gens

    I am going to go ahead and start this post so that the ones that read this will be able to find it in coming days. So here goes. I am a contractor at Ft Bragg. I am a generator tech. I will be posting ten 5k gens with service dates, hrs and serial numbers for those that wish to look for them on...
  5. P

    MEP-804A will not "excite" or "flash" whichever description preferred

    Yes, this is correct. Once a rpm range of 900 rpm is reached, which is sensed by the crank shaft senor/magnetic pickup, the start circuit is eliminated.
  6. P

    MEP-804A will not "excite" or "flash" whichever description preferred

    MEP-804A will not "excite" or "flash" whichever description preferred Afternoon all Hoping the gen guru's can assist me with this issue, so here goes. Working on a 804a gen, motor runs like a dream. Issue is this: Hertz is 60 and adjustable using the freq adjustment on the A5 card. Gauge...
  7. P

    MEP805A Issue

    Follow Up: 1.The AM/VM switch that was installed was a replacement of what had been installed by another party. After investigating parts it was concluded that not only was the switch not approved for the gen but also on one side of the switch the bridges, half were missing. Also the switch...
  8. P

    MEP805A Issue

    If you are calling the VM-AM switch a "selection switch" ,it was replaced with a new one and each individual terminal wire end was cleaned before reinstalling the wiring into the switch.
  9. P

    MEP805A Issue

    Hello everyone Welp new to the site,but read a lot. Believe in trying to answer my own questions before asking a question, when the information is there. But not so much this time. So here goes. I have a 805a gen that I am bringing back to life. Engine runs great now after doing some long...
  10. P

    815A Gen Issue

    Good afternoon I have a 815A Gen that has the following issue and am looking for assistance in diagnosing if possible. The engine runs fine operates as expected. The Generator portion however is giving me a fit. The issue is as follows. Once the engine has started and I engage the generator...