  1. C

    MEP-00# Exhaust Hose

    Awesome! I think I might give that a shot! If you have a moment would you mind posting a picture of your setup? I was thinking of putting the exhaust out of the top with a “tractor cap” to keep water out. From what I’ve read the ASK for the 002/003 directs the exhaust upward to reduce “noise”...
  2. C

    MEP-00# Exhaust Hose

    Did that reduce the volume? That’s my main goal here. What did you do for the exhaust? Sent from my iPhone using Tapatalk
  3. C

    MEP-00# Exhaust Hose

    Sent from my iPhone using Tapatalk
  4. C

    MEP-00# Exhaust Hose

    What would you guys think if I were to build an enclosure around my 002 on the trailer? It would attach to the trailer and be semi-permanent. I just finished about an hour at 92%. While it was running it checked for air flow. It seems that air intake is only on the front at the air intake (go...
  5. C

    MEP-00# Exhaust Hose

    Good Evening All, I have a MEP-002A mounted on a 3x5 garden trailer that I normally keep inside my garage. I would love to be able to run it in the garage due to the noise level and not wanting to unreasonably disturb my neighbors. While doing research online I found out that the M85 has 2...
  6. C

    MEP-002A Battery Charginig System Troubleshoot

    Hello All, I'm trying to verify that I have properly troubleshot my DC Charging System. My measurements are: Resistance Between Stator Leads (disconnected) - 0.9 Ω Left hand lead to ground - OPEN Right hand lead to ground - OPEN Stator disconnected and engine running - 43.2 VAC DC Voltage...
  7. C

    MEP-002A Spin-on Fuel/Water separator install question (WIX 24770)

    I'll try and get pictures. To clarify my question. how do you mount the new base into the location of the existing base. I'm good to go as far as the plumbing.
  8. C

    MEP-002A Spin-on Fuel/Water separator install question (WIX 24770)

    Good Afternoon All, So I ordered a WIX 24770 (adapter base) and a WIX 33405 (filter) to replace my the fuel/water separator on my MEP-002A as the original filter was missing and cost more than the replacement parts. Well today I received it and much to my surprise it doesn't just bolt on (some...
  9. C

    MEP-002A Voltage Adjust Reheostat (R1)

    Jim, You are a god send. I have the 72-5338 board. I had to turn it several turns to the left but it's there now (240 anyway). Thank you so much!
  10. C

    MEP-002A Voltage Adjust Reheostat (R1)

    Hello All, Today I noticed that when R1 is fully clockwise the output voltage is only 115/230VAC (on 120/240 1 phase). The TM says "Voltage readings should be as follows. Voltage adjust range shall be between 205 and 220V for the 120/208V, 3 phase, 4 wire connection. Between 114 and 126V for...
  11. C

    MEP-002A 30-Amp 125/250-Volt Black 4-Wire Grounding Convenience Outlet

    Wiring question for you guys. The norm is to wire the hots to L1 and L3. I was thinking that since I only want to supply 120 to my house why couldn't I just connect both hots to L1 and then it would seem to that it would balance the load from my breaker panel much better and allow the 56A to be...
  12. C

    MEP-002A 30-Amp 125/250-Volt Black 4-Wire Grounding Convenience Outlet

    So I added it today. Boy was that a pain. Whatever that big black block with the wires running thought it 50 times was a big pain. Anywho here are some pictures for your enjoyment. I connected the hot leads to terminal on CB1 where L1 and L3 connect. For common I connected it to the output...
  13. C

    MEP-002A 30-Amp 125/250-Volt Black 4-Wire Grounding Convenience Outlet

    Hello All, Has anyone here ever added a 30-Amp 125/250-Volt Black 4-Wire Grounding Convenience Outlet directly to their MEP-002A or MEP-003A? I'd like to add one to mine so that I don't have to use the TB1 connections. My thought was to connect a piece of 10/3 SJ00W to the same terminals...
  14. C

    MEP-002A Aux fuel cut off level

    I don't have a direct concern I just remember reading in the TM to keep the day tank as full as possible (of course I can't find it now). That lead me to believe that the aux pump would get the day tank to 100%. Just verifying. Thanks for the info!
  15. C

    MEP-002A Aux fuel cut off level

    Does anyone know at what level the Aux fuel pump is supposed to cutoff? Right now it looks like mine cuts off at just under 13/16 full. I can't find it in the pubs so I figure I'd ask you guys. Thanks in advance
  16. C

    PU-751m question

    Can anyone with a PU-751 tell me what the distance from the top of the MEP-002A (without ASK) and the bottom of the bows is? I have a MEP-002A (without ASK... for now) mounted on a 3x5 garden trailer and would like to make a cover for it. I want to ensure that I give proper clearance for...