Yep! , that's the layout. The inverter is a dual ExelTech XO series inverter. The battery was situated in the mid compartment , underneath the aluminum plate with all wire/lugs , and right is a HDM IXL 115/230 charger..still trying to figure out the possible wiring set-up , and also whether...
So Curiosity got the better of me and took the plunge. I was intrigued by this unit.. Inside it appears is a separate 2x2kw~ 4KW Inverter, and Battery Charger etc., the batteries had been removed I assume from a safety/storage point, unfortunately the wiring though intact is all over the...
Yes I'm beginning to think the same.. In any case, for the money they were asking for, I think i will be better getting a turnkey solar+battery set-up system..
Thanks to all!! much appreciated... I decided not to go ahead with this buy .. The company ZeroBase (or the new incarnation) told me they no longer manufacture or support this setup..It appears this may have been part of one of the numerous DOD Lab experiments with Hybrid Systems, not sure...
Going thru the spec sheet again, I think it may have its own inverter, however I am not familiar with this set-up at all so I will see if I can get any more info..
Fellow Steelers,
Greetings; and as usual let me start by saying thank you for any advice , suggestions or comments... I have the chance of getting hold of a "Hybrid" MEP-831A.. its has connectors for hooking up to a Lithium Iron battery backup unit and according to the literature I could...
Hello and much appreciate the response !. To be honest I am not sure what the gasket materials / seals are made off. The main components I assume have direct interface to the fuel are:- Fuel Filter; Pump; Separator. I will have to read the tech manuals to be certain.. In terms of power output...
Fellow Steelers, appreciate any guidance / advice. Is it ok to use Biodiesel in the MEP 802/803 and 531As? We have a combination of the above mentioned gensets and will be moving to a relatively remote area with access to good supply of vegetable oil~ Canola / Sunflower. We do have a rig for...
Fellow Steelers, appreciate any guidance / advice. Is it ok to use Biodiesel in the MEP 802/803 and 531As? We have a combination of the above mentioned gensets and will be moving to a relatively remote area with access to good supply of vegetable oil~ Canola / Sunflower. We do have a rig for...
Fellow Steelers,
G'day and trust everyone is well. Reaching out again to seek help. Our reliable 501A (28 DC) which had been reliable just stopped producing electricity ~ 0 volts showing) not sure what happened but we had tried to power up an 804A and thats when things quickly went...
Good Day All;
Have a general question and as ever really appreciate any response. Is it safe/ok to hook i.e wire up a compressor (3Phase, 26Amp , 9600W) directly to the 804A terminal i.e L1-L3 , G, N ?? OR is it advisable to go via a power distribution panel with 30amp circuit breakers? The...
Fellow Steelers, reaching out for advice. Recently obtained 2 MEP's; 802 & 804A..Will be used intermittently to test and validate certain pumps and items, however don't want to buy batteries and leave out in the cold at the mercy of the elements.. I have a small aircraft starter ~ Audio...
Update to my original post re transporting an MEP-804A mounted on a Trailer.
****update Mon 8 Nov***
I no longer need the trailer , rather more the Genset. is it easy to remove the bolts holding the Genset onto the Trailer?
Hello I was thinkin a Toyota Tundra truck.. I was adviced best to use a 3/4 Ton truck so will likely look to renting a FD 250...I am not really sure of the tire condition, so looks like another dimension I need to factor and decide whether its worth me towing or getting a tow company to...