• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Mep80Xa injector pump leak

Josephml21

Member
75
45
18
Location
PA
As the title says I have an injector pump leaking fuel. I've ripped the whole thing apart, cleaned it and replaced the o-ring on the high pressure side.

I double checked the fuel line and when I put in all back together today I replaced the hose clamp with a new crimp clamp on the low pressure side.

I've thought and tried just about everything I can think of so now I'm here looking for any insight. The leak appears to be coming from somewhere around the base of the IP and the block.

I did notice that when I blew air (from my mouth not compressed air) through the low pressure inlet it was leaking down to the bottom half where the spring and IP pushrod is. I've also noticed that my oil level is rising and it seems thinner leading me to believe that fuel is leaking down via this passage.

When I had the IP apart I looked like the only thing that is stopping fuel from leaking down would be the tight tolerances. Anyone heard of these things eventually wearing out?
 

Attachments

Last edited:

Ray70

Well-known member
2,595
5,914
113
Location
West greenwich/RI
Your oil level rising is a sure sign that you are leaking fuel into the crankcase, but other than damage or a crack near the fuel inlet, I don't know how you would be getting that fuel on the outside of the block.
I believe you are correct as far as the tolerances being the only "seal" internally around the plunger, but that being worn should only allow a leak into the crankcase, not externally, so possibly there are 2 issues.
How many hours do you have on the machine and is it only one metering pump leaking or all of them?
Also, in the picture it looks like the pump is sitting up off the block and not tightened down, but that still doesn't explain the fuel leak.
Maybe you could start by trying to clean it all off, drying it and just run the pump to see if the fuel leak comes back with just the pressure from the transfer pump, if not then proceed to check it again while running.
 

Guyfang

Moderator
Staff member
Moderator
16,768
24,102
113
Location
Burgkunstadt, Germany
Something from the picture just is not right in my head. Yeah, maybe the IP is not far enough down. Are you sure that the thrust cup and the TAPPET,ENGINE POPPET are in right? Something seems odd.
 

Josephml21

Member
75
45
18
Location
PA
Something from the picture just is not right in my head. Yeah, maybe the IP is not far enough down. Are you sure that the thrust cup and the TAPPET,ENGINE POPPET are in right? Something seems odd.
Your oil level rising is a sure sign that you are leaking fuel into the crankcase, but other than damage or a crack near the fuel inlet, I don't know how you would be getting that fuel on the outside of the block.
I believe you are correct as far as the tolerances being the only "seal" internally around the plunger, but that being worn should only allow a leak into the crankcase, not externally, so possibly there are 2 issues.
How many hours do you have on the machine and is it only one metering pump leaking or all of them?
Also, in the picture it looks like the pump is sitting up off the block and not tightened down, but that still doesn't explain the fuel leak.
Maybe you could start by trying to clean it all off, drying it and just run the pump to see if the fuel leak comes back with just the pressure from the transfer pump, if not then proceed to check it again while running.
The fuel leak was around the IP inlet fitting where the low pressure hose connects. I had a guy run a bead of weld around it and it stopped. I'll get pics up in a few days.

Once I got it all back together I gave it a test run to check for leaks and it ran fine for a few minutes then sputtered out. Water separator was full. Once I solved that issue it runs but the engine won't run under a load. I don't know what is going on anymore I'm just gonna have to start back at square one work the problem.

And to answer the questions everything looks and feels in place. I only remove one IP at a time and never had to wrestle out or in an IP. It was only the one that was leaking. And the set has about 2600hrs on it. It's been mine the whole time and has always ran fine. Im probably just overlooking something in regards to the engine not wanting a load on it.
 
Last edited by a moderator:

Josephml21

Member
75
45
18
Location
PA
The plot thickens. So I decided to pull the other IP and disassemble it to compare because prior to this I've only disassembled the leaking IP.

I've laid out the two, so the IP on the right is the untouched one. It has two extra parts that the other one does not. I've also attach a pic of where it was leaking from and the weld job that stopped the leak.

Can anyone that has experience with these tell me what the correct amount of washers/rings is. The TM does not go in depth (exploded view) for the IP's.

Additionally anyone know where I could source these missing parts? I've already found a supplier for the whole IP but I really don't feel like buying a whole new part when this one is still serviceable.

Thanks

PXL_20220504_000738230.jpgPXL_20220504_000738230.jpgPXL_20220504_000808901.jpgPXL_20220504_000835003.jpgPXL_20220504_000738230.jpgPXL_20220504_000808901.jpgPXL_20220504_000835003.jpgPXL_20220504_000738230.jpgPXL_20220504_000808901.jpgPXL_20220504_000835003.jpgPXL_20220504_000738230.jpgPXL_20220504_000808901.jpgPXL_20220504_000835003.jpgPXL_20220504_000738230.jpgPXL_20220504_000808901.jpgPXL_20220504_000835003.jpg
 

Josephml21

Member
75
45
18
Location
PA
There are at least 2 different manufacturers that make these metering pumps with similar but slightly different designs.
Do both of yours have the same part # stamped on them? I can't quite tell from the pictures.
I everything stamped on the housings match exactly. The LP part number, a TPF# and the delphi-II markings are all the same.
 

uniquify

Active member
228
223
43
Location
Sioux Falls, SD
Here is some part number info for the injection metering pumps for the Lister-Petter LPW2 & LPW4 (aka Cummins Onan DN2M & DN4M):

Lister-Petter Part#OEMOEM Part#
751-41173StanadynePF70/31466
751-41174ADelphiTPF1Q070T3502


Here's a picture of the guts of the Stanadyne version:
MeteringPump_751-41173_Stanadyne.jpgMeteringPump_751-41173_Stanadyne_grouped.jpg
 

Guyfang

Moderator
Staff member
Moderator
16,768
24,102
113
Location
Burgkunstadt, Germany
Whats the cost of two new IP's? I would never feel good about using something someone else screwed up. And the welded of in any case.
 

Guyfang

Moderator
Staff member
Moderator
16,768
24,102
113
Location
Burgkunstadt, Germany
Maybe you need to read the -24 TM. There is a procedure on how to do that. You can also send @Ray70 a PM and ask him. He is really very good at that. Or look back at one of his threads where he writes about the procedure.
 

Ray70

Well-known member
2,595
5,914
113
Location
West greenwich/RI
Here are my thoughts:
In the past we had determined there is a mistake in the TM where is calls the "X" dimension 2.02", that is an error. X should be 2.20", however, experience has shown me that when working on a motor with unknown pump shim requirements, putting 2 black shims under the pump and pushing the fuel inlet all the way against the pushrod tube seems to work every time.
In your case when replacing an existing pump I would use the same shims as you have now , push the inlet against the pushrod tube and call it a day!
You are correct in that a new pump = new clearances but I've found that the shim thickness really is not that critical to engine performance.
 

Josephml21

Member
75
45
18
Location
PA
Here are my thoughts:
In the past we had determined there is a mistake in the TM where is calls the "X" dimension 2.02", that is an error. X should be 2.20", however, experience has shown me that when working on a motor with unknown pump shim requirements, putting 2 black shims under the pump and pushing the fuel inlet all the way against the pushrod tube seems to work every time.
In your case when replacing an existing pump I would use the same shims as you have now , push the inlet against the pushrod tube and call it a day!
You are correct in that a new pump = new clearances but I've found that the shim thickness really is not that critical to engine performance.
Thanks for clearing that up, I was concerned that it would be a pain in the butt to get the shim thickness correct
 

Josephml21

Member
75
45
18
Location
PA
Here are my thoughts:
In the past we had determined there is a mistake in the TM where is calls the "X" dimension 2.02", that is an error. X should be 2.20", however, experience has shown me that when working on a motor with unknown pump shim requirements, putting 2 black shims under the pump and pushing the fuel inlet all the way against the pushrod tube seems to work every time.
In your case when replacing an existing pump I would use the same shims as you have now , push the inlet against the pushrod tube and call it a day!
You are correct in that a new pump = new clearances but I've found that the shim thickness really is not that critical to engine performance.
I should have asked but I didn't think about it until now. You can hit a pushrod tube going in both directions. Did you turn the IP clockwise or counterclockwise to hit the pushrod tube?
 
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks