  1. deercoker

    Flashing Gen Lights (Both)

    Checked voltage at plugs with key off and key on per Warthog and they check good, load tested batteries and they are good, voltage across both not running is 25.0 volts, running voltage is 29.8. Cleaned all bussbar connections, battery terminals but have not checked firewall plug yet. Both gen...
  2. deercoker

    Heat stopped working

    Changed the thermostat to the 22 dollar one from napa and found that it had the same one in (hockey puck type) but the plastic puck was stuck at an angle so it was not working, it got dark so did not have time to look at it further to check manufacturer but long story short, ran it with cap off...
  3. deercoker

    Heat stopped working

    So no coolant loss? if it is burned burned off in the combustion chamber it is not replaced right? I am not nearly as knowledgeable as you about the head gasket situation but I would imagine coolant loss at some point, not arguing just trying to understand! I think the easiest first is the...
  4. deercoker

    Heat stopped working

    I will have someone pressure test the cooling system, I can't see changing a head gasket unless bad, one would think a blown head gasket would also have other symptoms as well, Thanks cucvrus
  5. deercoker

    Heat stopped working

    so does the level in the overflow tank after driving 30 miles 2" above cold level sound right?
  6. deercoker

    Heat stopped working

    I checked the over flow this morning and it was at the cold mark, I drove it 30 miles and after 5 miles the heat was lukewarm and stayed that way till I got home, I checked the overflow again while hot and it was about 2 inches above the cold mark. This is the 3rd M1009 I have owned and I don't...
  7. deercoker

    Heat stopped working

    air in system maybe?
  8. deercoker

    Heat stopped working

    I guess you could say that, worked fine on the interstate (for a cucv) but not sitting or a lower speeds, have not had it over 50 mph since I brought it home, the coolant level is good and appears to be clean.
  9. deercoker

    Heat stopped working

    I don't have a thermometer to check coolant temp, funny thing is I drove it back a couple weeks ago fro Chattanooga where I bought it about 3.5 hour drive and the heat worked fine, the guy I bought it from told me the heat did not work so it surprised me when it did. However it has not worked...
  10. deercoker

    Heat stopped working

    well the cables are moving freely and you can hear the doors opening and closing, bad heater core maybe?
  11. deercoker

    Heat stopped working

    Thanks cucvrus, I will check'em and let all know tomorrow
  12. deercoker

    Heat stopped working

    hoses are warm If the hoses are warm could if be the blend door in the dash and where exactly is it?
  13. deercoker

    Flashing Gen Lights (Both)

    I just replaced my swellman plow plugs with ac60g's and new connectors, bypassed the resistor and installed a new glow plug relay, now both gen lights flash no matter the speed, what did I do?
  14. deercoker

    Flashing Gen Lights (Both)

    I guess that means the backside of the fuse box inside the firewall?
  15. deercoker

    Flashing Gen Lights (Both)

    Thanks doghead, I will go back and check all grounds and the firewall plug,
  16. deercoker

    Flashing Gen Lights (Both)

    what is the drivers side thru firewall plug on a cucv?
  17. deercoker

    CUCV four color MERDC camo?

    yea I painted my last one using the ambulance pattern as I could not find one for the M1009, I think it was MERDC Summer, the one in my picture I painted the 3 color woodland paint scheme, this one is 4 color
  18. deercoker

    Recovery planned, Dayton, Ohio to Spartanburg,SC this coming Friday

    I'm in Jonesborough Tn just off I-81, wouldn't mind droppin in line for a ways just for the heck of it.
  19. deercoker

    cucv altenator

    My auto electric man found the bulb receptacle contacts for the generator were corroded and once he cleaned up the instrument cluster everything is working fine he says, voltage staying around 14.6 when running, I'll pick it up in the morning and hope it's OK, thanks
  20. deercoker

    cucv altenator

    anybody know what the brown wire with white strip does that comes out of the 2 wire plug from the altenator to the fuse box? the fuse box is as far as I've traced it.
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock