  1. Digger556

    Generator not starting right

    Did he mean voltage regulator? Multiple things not working at once usually points to a ground issue. If he swapped a component and now it won't start, there is a good chance he didn't put it back together exactly the same way.
  2. Digger556

    mep803a odd oil leak help

    I would look at the oil drain or rear main.
  3. Digger556

    MFC Bung Adapter for drum

    Saw your location, stay safe out there. Really terrible what is happening in your AO.
  4. Digger556

    East Coast Winter Storm - JAN 10

    I love it! Way to be proactive. I was in KC for the blizzard last weekend. Spent a lot of time prepping generators, chainsaws, tractors, and firewood with my inlaws.
  5. Digger556

    Mep 802a bogs down when a/c circuit interrupt

    I have "safety wire" from my racing days, but I remember my grandfather always had two things on his person when we were out on the tractor, pliers and a roll of bailing wire.
  6. Digger556

    Mep 802a bogs down when a/c circuit interrupt

    Check these wires behind the fuel/water separator. They connect the circuit interrupter contactor and the output lugs. Despite them being routed through a P-clamp, they can still rub on the edge of the sheet metal, which is compounded by how much an 802 shakes when running. Here is an example...
  7. Digger556

    Question about synchronizing transfer switches

    I was kicking around DIY'ing a synchronized transfer switch. and wanted to understand the level of tech that went into the official units. My Outback and Xantrex inverters use a transfer switch, but they don't make much of an effort to match voltage. They just get it close, match the phase and...
  8. Digger556

    Question about synchronizing transfer switches

    Thanks guys. The schematic is enough for now.
  9. Digger556

    Question about synchronizing transfer switches

    Specifically the ones used with the MEP-802a and 803a power plants. 1) which TM has a wiring diagram for these units? 2) Are these open or closed transition transfer switches?
  10. Digger556

    Merry Christmas Everyone

    I'll be honest, I was hoping for a snow storm to knock out the power. :LOL:
  11. Digger556

    Merry Christmas Everyone

    Merry Christmas!
  12. Digger556

    Hello - new MEP-803a owner here

    Missing battery trays and hold-downs are pretty normal. The unit I just picked up is the most complete to date and is still missing one tray and the hold down. 1300 is still low hours and odds are good it just needs some PMs and batteries. I would go ahead and swap the IP feedlines amd return...
  13. Digger556

    Mounting an MEP 802A on a Dodge Ram 2500

    Is your truck a manual? If so, you should have the NV4500 transmission which has a pair of PTO ports. With the PTO you could drive pumps and generators from your existing powerrain. This is very common with accessories like knuckle cranes.
  14. Digger556

    Milton after action

    Whole-heartledy agree with this. Minimum two, but three is a solid long term plan. Also, have the ability to run from multiple fuel sources, your fuel type may become limited. I keep a couple of gas inverter generators for light loads and backup.
  15. Digger556

    Currently Running a MEP-803a During Beryl Hurricane - Question

    Nice load banks you got there
  16. Digger556

    Addressing MEP-802a vibration

    In retrospect, I wish I would have while it was apart. The runout was so bad, I thought for sure that was the issue.
  17. Digger556

    Addressing MEP-802a vibration

    Copy that Guyfang! I pulled this thing apart last year and measured considerable runout at the end of the rotor shaft. Some was flexing of the [35] plate, but I fully disassembled the whole rotor, adapter plate and flywheel, measuring excessive runout on each interface. I've designed and...
  18. Digger556

    Addressing MEP-802a vibration

    Havent run a compression test, but it pops off and seems to run strong under load. I was only able to load test it in short bursts because I kept getting an overload shutdown alarm. I have since use Deoxit on the mode switch and need to retest. This unit sat in Missouri for a long time in...
  19. Digger556

    Addressing MEP-802a vibration

    :D This is definitely a type II fun project with no expectation of ROI. I like the 802's, but don't accept the level of vibration, even out of good running units. If I could spec an alternate isolator that resulted in 25% reduction in vibration, I would consider that a win. If I could get 50% or...
  20. Digger556

    Addressing MEP-802a vibration

    Unfortunately yes. Of the three running 802a's, I'm not sure why this one particular unit shakes more, but I still need to verify the injectors are functioning correctly (pop test) and play with the timing slightly to see if that makes a difference. My nicest, newest unit is a 200 hr machine...