• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. jmenende

    How To Repair HMMWV EESS S3

    I have the exact same issue with my nartron smart start box even after new plugs. Wait light turns off and its still sending 24v to the plugs and never out of the yellow. I hear the clunk turn off when turn off the vehicle. Any suggestions?
  2. jmenende

    Any master mechanics of LMTV willing to travel to Puerto Rico?

    You planning to move over here?
  3. jmenende

    Any master mechanics of LMTV willing to travel to Puerto Rico?

    The trucks have all been bought locally. Hacienda will charge you taxes of you want to register it and tag it. If you plan to bring it over, just leave it with your own tag.
  4. jmenende

    Any master mechanics of LMTV willing to travel to Puerto Rico?

    Yeah. I actually got around to do it and both are running but not perfect. Im waiting on some parts.
  5. jmenende

    Air Brake Info and Troubleshooting

    Cant find and RN11V or RN31BC kits in stock. All backordered. Looks like im grounded.
  6. jmenende

    Looking for LMTV mechanic willing to travel

    Engine is not an issue, its the other electronics, air and hydraulic systems. Allison is another issue altogether. Id rather have someone who has allaround experience with this platform and not some youngblood with a computer who cant see past whatever the computer says and thats what id figure...
  7. jmenende

    Looking for LMTV mechanic willing to travel

    Im looking for an lmtv mechanic thats willing to travel. I have 2 m1078a1 with issues and I cant find the time to work on them and I cant let them go to waste. I have a generator repair shop so all tools will be available.
  8. jmenende

    Who restores cucv on the east coast

    Yeah, I know Rick is the best. I sent him a message and Im just waiting for his reply. Thanks
  9. jmenende

    Inspection needed on m1009 Albany

    Howdy folks. Im looking at an m1009 cucv in albany Ny and would like someone to take a look. Any takers? Your time will be compensated.
  10. jmenende

    Who restores cucv on the east coast

    Howdy gents. Looking at an m1009 that i need it looked over and maybe restored. Who does this in thr east coast?
  11. jmenende

    MEP 802A Fix-up Thread 3.0

    anyone know of a replacement voltmeter available that will fit the same size hole on the panel?
  12. jmenende

    MEP-805 Frequency Fluctuation

    Ohh boy. Low voltage makes havoc on the 805b and 806b cim module. Causes it to restart etc. So yes, weak batteries and an alternator not rotating at the correct speed will affect the unit.
  13. jmenende

    MEP-802/803 load bank info

    I live in hot weather all year and load bank these units to 12-14kw right off the bat (10 seconds after start). Thats real world scenario for these units. If they are gonna leave my shop, they must pass this test and run for 1 hour at atleast at 12kw surging to 14kw. Thats also the best way to...
  14. jmenende

    MEP-805 Frequency Fluctuation

    Check the mag pickup. Could be sending incorrect reading to the governor and thus messing with the actuator. Check for 2.8-3vac. If not, remove, clean and readjust tgr mpu. The TM has the procedure. If this does not help, try to rule out the IP by releasing the linkage and setting it manually to...
  15. jmenende

    Yet another MEP805B issue I need advice on

    Btw, just got a unit in pristine condition and found this inside. 90's throwback.
  16. jmenende

    2 Humvees from madison Ga to Jacksonville.

    Looking to transport 2 humvees to the port of jacksonville.
  17. jmenende

    Yet another MEP805B issue I need advice on

    Thanks Mac/Mc for helping keep these units alive and original.
  18. jmenende

    Mep-1050, mep-1051, 4-1050, 4-1051

    So this is what I learned today while tinkering with the 15kw. I swapped (2) 60kw control cubicles and they registered as 15kw units immediately on display with no changes made by me in the configuration. Only got a message that the configuration changed and the message went away after I hit...
  19. jmenende

    Mep-1050, mep-1051, 4-1050, 4-1051

    Ok. Confirmed it has 12 same sized wires. Also has the f1,f2 and another pair. The genhead plate specifies 120/240 @doble delta. There is hope.
  20. jmenende

    Mep-1050, mep-1051, 4-1050, 4-1051

    Will do once i get back to the yard tommorow.