  1. D

    MEP016D Starting Issues - Grrrrrrrr...

    Just thought of another thing to try before tearing anything apart. You have fuel, and air, but not enough heat to light off the fuel. Try heating the cylinder and air intake with a heat gun or hair drier, to the point that they are uncomfortable to touch, then, while blowing hot air into the...
  2. D

    MEP016D Starting Issues - Grrrrrrrr...

    Don't let that stop you. You currently have an engine that does not work. If you are careful when you disassemble it, you can't make it any worse. Taking the head off is the first and easiest step. Take plenty of pictures when working on it, that way you have something to look at when...
  3. D

    MEP016D Starting Issues - Grrrrrrrr...

    I would take off the valve cover, and check the valve clearances before tearing the engine apart. Thats only two bolts. Maybe a valve is stuck open. Just be careful not to damage the gasket when you pull the cover off.
  4. D

    Dipstick oil heater or?

    I use the Kat's brand; It's a good brand, but there are also others. I use a 250 watt unit on my hummer oil pan (2 gallons). Never have an issue starting it in cold weather, but the lowest I have seen here, north of Flagstaff is about 0F. If you get the pad style, make sure you follow the...
  5. D

    MEP-803A Repair Assistance

    You can also pull off the fuel return line at the tank and point it into the tank fill opening (you might have to add a short piece of hose). See if fuel comes out, but stops flowing when the machine starts to droop. Then you will know if its a fuel delivery problem. Any chance the pump is...
  6. D

    Using 28vdc to start MEP-804A

    The 2870 will output 70 amps, before it will safely shut down on overload. I have never measured my 802a starting current, but it might be enough to get it started since it is a small engine. Not sure about the larger 804A. (Has anyone here measured the starting current on an 802a while cranking?)
  7. D

    MEP-802a Power on only 1 leg?

    Since 3 phase works good, it is not a generator problem. Did this generator ever work correctly on single phase? Sounds like a wiring or switch problem. Based on how single phase is derived, it could be that one of the windings is reversed or disconnected when the switch is set to single phase...
  8. D

    How long do you store your diesel fuel

    I store my diesel in MFC's, with Biobor and PRI-D added. I usually rotate the fuel at 5 year intervals, although I tested one by keeping it 9 years, with no problems. Water, heat, oxygen, and certain metals are the enemy of diesel (and other fuel as well). Open tanks that can breath are the...
  9. D

    MEP-831 A overload problems

    How do you know that the generator is the problem, and not the air conditioner? I spent hours trouble shooting a motor starter / motor circuit once, only to find out the device connected to the motor had mechanical issues, causing the starting overload. Can you connect another large load /...
  10. D

    How to install Head Gasket on MEP 813-A

    Ignore my previous message. I read 831, not 813. Should have looked at the posted TM number.
  11. D

    How to install Head Gasket on MEP 813-A

    No sealant is used on the headgasket. Just make sure all your surfaces and gasket are absolutely clean, then evenly torque the cylinder nuts. I don't like to go directly to the final torque. I usually go to 15 ft/lbs first, then to the final torque (same as the Yanmar manual).
  12. D

    MEP-803A no start

    Do you have compression? Can you hear the starter motor bog down on the compression stroke, or does it just whine like it's turning easy? Can you feel air blowing out the exhaust while cranking? If so, can you smell raw diesel? Is the fuel good?
  13. D

    Mep-531a Hz too low

    Run your engine with the discs off to see if the RPM comes up. It won't hurt the machine to run without the discs.
  14. D

    MEP-501A Voltage/Load Gauges Inop

    Since both gauges are not working, there is a possibility that the set is wired wrong, or has been "re-wired". Check your voltmeters with a power supply, or a 9 volt battery to se if they work. Don't check the load gauge with a battery or power supply. That gauge has a 50mv full scale...
  15. D

    genset loadbanks

    I use a surplus Fostoria industrial heater just like this one - Surplus Fostoria FES-1524-1A Space Heater (Not sure if I can post the complete link, but this one is on GovPlanet right now). This is a 15kw 240v single phase heater. The heater consists of six 2500 watt heating elements...
  16. D

    Mep531a mounting plate nsn

    If it is the round filter mounting plate that attaches to the air preheater, you can just get a piece of eighth inch aluminum and make your own. It doesn't even have to be perfectly round. Drill enough holes for the engine to get enough air, and leave a strip of metal across the center to attach...
  17. D

    Tank Blanketing, for long term storage on big tanks?

    You will also need an upstream regulator on the cylinder, to drop the pressure to a level acceptable to the purge regulator. The purge regulator most likely cannot handle the 2200 psi from the cylinder directly.
  18. D

    MEP-802A short/fire

    Same problem on mine. Original, with 500 hours. I caught it before the sparks flew, while inspecting the machine with the top off. I used fuel hose to sleve the wires, and wire ties to hold them together. The insulation was chafed about 1/2 way through on one of the wires.
  19. D

    Modern digital generator controller conversion?

    Nice looking control panel. Here is my 2 cents worth - One reason I have a MEP-802 and MEP-16's and 531's is because they are extremely simple and easy to work on, which makes them reliable from my point of view. After working with fancy computer controlled generators for many years, I prefer...