• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. 155mm

    Actual Rating for MEP-804B

    Jeff, you do understand that an 804 is a 10 wire not 12, correct?
  2. 155mm

    Actual Rating for MEP-804B

    Yanmar turbo motor is only thing i know of, someone else will pipe up and correct me
  3. 155mm

    Actual Rating for MEP-804B

    804 is a 10 wire head, not 12. I load tested my 804a at 18k with no issues, it didn't like 21k. The video is after a used motor swap, so it was smoking more than normal to blow out the cobwebs https://youtu.be/HZuCSmFHLV4
  4. 155mm

    MEP 804b MPU source?

    I had a ghost also on a 805, got mad, disassembled whole control coupla, put it all back together. I didn’t fix anything, but this day, its the most reliable. my guess is corrosion or bad connection, now the $10k question, which one.
  5. 155mm

    MEP 805B Screen Backlight Issue

    Sorry i didnt ask if you had a color screen or monochrome. It would have saved you the building of the tool.
  6. 155mm

    MEP 805B Screen Backlight Issue

    Color screens require backlight to be on, so turn the dashboard lights on when you turn on master
  7. 155mm

    Size of Generator needed

    Thats only single ph 240, so 10kw is max
  8. 155mm

    Size of Generator needed

    Photo the breakers and post
  9. 155mm

    Size of Generator needed

    Is it a military shelter prewired? If yes, what is thesize of the main breaker?
  10. 155mm

    J1939 diagnostic code reader. Anyone using it?

    I dont know mtvr, does it have a cat? CatET is required for much of cat access
  11. 155mm

    MEP 804b MPU source?

    You can operate injection pump by hand, for troubleshooting. Takes 2 soldiers unless you have really long arms. My guess is mpu same as robert. Unless something got knocked loose with the tip over. Might check all relays behind control panel
  12. 155mm

    MEP 804b MPU source?

    Correct, the small mpu on 804 is the speed sensor on the tranny on an 03 379 pete, the large is on an 03 w900 kenworth tranny
  13. 155mm

    Fermont MEP-804A output

    804 is a 10 wire genny. There are 2 ground wires bonded in the head 004 is a 12 wire, therefore it can be rewired as a dogleg wye
  14. 155mm

    Fermont MEP-804A output

    Can not be done
  15. 155mm

    MEP 805B No voltage at load output terminal board

    Parts were not easy to find. Board came from china, 2 weeks, 100 pin cable from italy or greece, and he sent a 50 pin first time by accident.
  16. 155mm

    MEP 805B won’t shut off

    Use that link, it has all troubleshooting. If you remove gov actuator, take out bolts, and be easy, it slides to remove, and don’t destroy gasket when sliding. There is fuel in there as well
  17. 155mm

    MEP 805B won’t shut off

    Disconnect line at tank, or before fuel pump, no possible way for that line to have pressure, it’s suction.
  18. 155mm

    MEP 805B won’t shut off

    It only has one pickup line, right side under alternator, goes to fuel pump then filter. The line on left side is returned fuel
  19. 155mm

    MEP 805B won’t shut off

    Take line loose at tank or before pump
  20. 155mm

    MEP 805B won’t shut off

    You are having governor actuator issues.if you cant manually shut down, loosen fuel supply line at injection pump