  1. K

    Looking for interrupt switch

    When you lift the switch UP and hold it up does the green contactor light illuminate? Does it then go out when you release the switch? These switch's seldom go bad so I'd suspect the issue with the contactor not closing is due to something else.
  2. K

    MEP-803a not making full power/tripping overload

    Usually not a serious issue. Usually due to poor contacts in either S6 and/or S8. Can usually be resolved using some contact cleaner such as Deoxit.
  3. K

    Spare parts question

    There are two diode assemblies in the gen head. 5961-01-019-8003 Onan PN 358-0070 Can be found on ebay and 5961-01-021-2232 Onan PN 358-0069 Can be found on ebay
  4. K

    Trouble with the 3k inverter

    My suspicion is that moisture gets into the unsealed potentiometers on the main control board inside the inverter causing their resistance values to change. The potentiometers are there so that the manufacturer can adjust parameters such as the Short Circuit threshold and a number of other trip...
  5. K

    MEP-804A, MEP-804B, MEP-805A, MEP-806A Replacement A1 AC Voltage Regulator

    MEP-804A, MEP-804B, MEP-805A, MEP-806A Replacement A1 AC Voltage Regulator Posted this in the wrong section. See my my listing in the Classifieds for info. See link in signature
  6. K

    MEP-804B

    The Remote Start systems are now available for the MEP-804A, MEP-804B, MEP-805A & MEP-806A generators! See link in my signature to navigate to the listings.
  7. K

    MEP-803A Injector Pipe Nut Torque Value Wrong in Manual

    Earlier in the manual in 3-12 it does call out "Tighten injector pipe nut (2) to 21 ft-lbs (28.5 Nm)." It would look like 21 ft-lbs is the correct value.
  8. K

    MEP-804B

    Need to do one more test in an 804 before calling it good. The %Load measurement was a bit off and want to get that solid before releasing it. Wife had a medical issue recently and that took priority. All better now. Good news is it will support the MEP-804A, MEP-804B, MEP805A & MEP-806A.
  9. K

    MEP-007A TM's and actual filter #'s

    Two possibilities... TECHNICAL MANUAL INTERMEDIATE [FIELD] [DIRECT AND GENERAL SUPPORT] AND DEPOT LEVEL MAINTENANCE Liberated Manuals - Search Results for 007A
  10. K

    Pulse Tech 24V Solar Chargers, which is the correct one for MEP-803A ?

    I haven't mounted them yet. They are a pair of wall wart Battery Tender chargers I had laying around so they are just plugged into the AC inlet and laying on the floor of the skid.
  11. K

    Pulse Tech 24V Solar Chargers, which is the correct one for MEP-803A ?

    That's the exact same place I installed my NOCO power inlet port on my 802A
  12. K

    75902lv Master Start Switch for MEP-80x Gens. Who has one for sale?

    Billy2642 has made good on this. I received a replacement 75902LV in the mail today.
  13. K

    MEP-804B

    I don't have any specific recommendation on a transfer switch. There is such a variety of them available with various features such as load shedding and other feature sone might desire in the transfer switch for their specific application and generator used. A transfer switch or other...
  14. K

    Mep-802a - amp meter not working.

    There is no fuse in that circuit. The two small wires on the front screws of MT4 go directly to M4. The wire numbers are 158A & 159A. M4 is a voltmeter that measures the small DC voltage that develops across MT4 while the battery is discharging and charging. After starting the genset the meter...
  15. K

    Mep-802a - amp meter not working.

    None of the switches have any affect on the battery charge/discharge meter. That meter is connected directly across the MT4 shunt in the right front corner behind the meter panel. MT4 is a shut (very low resistance resistor). The voltage drop across it is measured by the charge/discharge...
  16. K

    MEP-831a Wont turn off

    Anytime :)
  17. K

    MEP-831a Wont turn off

    The gap should be zero when it's off. IE the target on the arm should be against the magnet when the set is stopped.. When the set is running at no load the gap should be 5/16" There is an adjustment procedure in the -13 TM on how to set the gap at no load. The gap has to be set correctly so...
  18. K

    MEP-831a Wont turn off

    K15 is the starter cut out relay. It's normal for the LED inside ot to be on once the set has started. I see a few issues in the picture 1) The green spring for the governor is in the wrong hole in the arm. 2) The gap between the magnet and the target is way to wide. It should be 5/16"...
  19. K

    MEP-802 and 803 Main generator tip.

    Glad to help! Yes the PN for the MOV is correct.
  20. K

    MEP-802 and 803 Main generator tip.

    The MOV mod is actually something I came up with a few years ago. It purpose is to protect the VR from shorting out. Something the Fuse Mod doesn't do. If the fuse were to pop the MOV should still be good.