• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. C

    Mep004 circuit to replace faulty voltage regulator. This was designed by member peapvp for use until he could rebuild and update the operating l.

    I have lived by the old saying "chrome don't get you home" and I agree with Peter it isn't pretty, but it does work flawlessly. I used this setup for approx. 12-15 hours for back-up. Storms and living in the woods doesn't always keep the lights on. I tried to go back and see the cost of parts...
  2. C

    Mep004 circuit to replace faulty voltage regulator. This was designed by member peapvp for use until he could rebuild and update the operating l.

    Mep004 circuit to replace faulty voltage regulator. This was designed by member peapvp for use until he could rebuild and update the operating l.
  3. C

    Automatic / Manual Fieldflash with aftermarket AVR on MEP004A / 005A

    Can it be set up to manually excite? The generator doesn't automatic start.
  4. C

    Automatic / Manual Fieldflash with aftermarket AVR on MEP004A / 005A

    Peter, if there is a possibility that the 054 is damaged, I will not replace it with another one. I am only trying to have this for emergency use until I can get the VR shipped and rebuilt. Is there any way to check the unit without having to buy anything else? Am I beating a dead horse? I don't...
  5. C

    mep004 reads 0 phase to phase 480 phase to ground

    Thank you, Mike
  6. C

    mep004 reads 0 phase to phase 480 phase to ground

    Anyone know a part no. for the diodes? I would like to have them here before I tear it apart. Thanks, Mike
  7. C

    mep004 reads 0 phase to phase 480 phase to ground

    resistor- Dale CW-5 56 ohm 5% 8815 diode- 1n5406 MIC Circuit now goes 24vdc off circuit breaker on rear of control panel-momentary push button-button to resistor- resistor to diode- diode to F1 (grey stripe end) F2 to chassis ground When button pushed 24.9vdc on meter. Nothing else in circuit...
  8. C

    mep004 reads 0 phase to phase 480 phase to ground

    24v to push button- push button to F+ or F1? Resistor and diode go where?
  9. C

    mep004 reads 0 phase to phase 480 phase to ground

    A to C .8 volts, F1to F2 .003vdc running with main contactor on, pushbutton pushed and released. Not running 24vdc @ pushbutton 1.7 volt across F1-F2 with button down. I looked and don't have a 24v relay unless there is one in the old vr box.
  10. C

    mep004 reads 0 phase to phase 480 phase to ground

    Thanks for the reply, I will start back on it this morning. I don't have a 24v relay here, will try to get one from Caterpillar tomorrow if i can. There aren't any supply houses close by have to order everything. I will get the voltage measurements you asked for. Thanks, again, Mike
  11. C

    mep004 reads 0 phase to phase 480 phase to ground

    Should the original vr box be disconnected? Both connectors?
  12. C

    mep004 reads 0 phase to phase 480 phase to ground

    I think I'm in over my head. Is there a simple way to test gen leads with a voltmeter to make sure gen is still good? As much as I would like to keep what I have, if the gen is bad, would I not be better off to replace it with a more modern gen head? Power was off again for 5 hours this morning...
  13. C

    mep004 reads 0 phase to phase 480 phase to ground

    Measuring from L1,2 or 3 to L0 Thanks, Mike
  14. C

    mep004 reads 0 phase to phase 480 phase to ground

    Gentlemen, I am working on information given to me by a member jamawieb. He said he had used this set up with the ADVR 54 and the momentary push button, diode and resistor on different generators. Long story short start switch corroded a lug and had to replace. Worked after replacement. Future...
  15. C

    mep004 reads 0 phase to phase 480 phase to ground

    Sorry, and a momentary push button.
  16. C

    mep004 reads 0 phase to phase 480 phase to ground

    Added circuit from dc breaker to F1 with diode and resistor
  17. C

    mep004 reads 0 phase to phase 480 phase to ground

    At L1,2,3, to ground lug 480 L1 to L2 or L2 to L3 0 volts
  18. C

    mep004 reads 0 phase to phase 480 phase to ground

    Replaced regulator static exciter with aftermarket advr 54 and added exciter circuit. Get 0 volts phase to phase 480 phase to ground. Any ideas?
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks